- HEX TITLE 'CONVERT OBJECT DECKS TO HEX FOR NETWORK TRANSMISSION'
- HEX CSECT
- STM 14,12,12(13) SAVE REGISTERS
- BALR 12,0 LOAD BASE REGISTER
- USING *,12
- ST 13,SAVE+4 CHAIN SAVE AREAS
- LA 13,SAVE
- L 11,0(,1) POINTER TO PARM FIELD
- LH 11,0(,11) LENGTH OF PARM FIELD
- OPEN (INPUT,(INPUT),OUTPUT,(OUTPUT)) OPEN DATA SETS
- READ GET INPUT,INCARD READ A CARD
- CLC INCARD(2),=C'./' IEBUPDTE CONTROL CARD?
- BE ONECARD
- LTR 11,11 WAS PARM FIELD SPECIFIED?
- BZ DOCARD BR IF NOT
- CLC INCARD(4),=AL1(X'02',C'S',C'Y',C'M') SYM CARD
- BE READ SKIP IT IF SO
- DOCARD LA 2,INCARD SET UP HEX CONVERSION LOOP
- LA 3,OUTCARD
- LA 4,80/4
- DOHEX UNPK 0(9,3),0(5,2) CONVERT 4 BYTES TO HEX
- LA 2,4(,2)
- LA 3,8(,3)
- BCT 4,DOHEX
- TR OUTCARD(160),HEXTBL-C'0' CONVERT TO PRINTABLE CHARS
- PUT OUTPUT,OUTCARD WRITE HEXED CARD AS 2 RECORDS
- PUT OUTPUT,OUTCARD+80
- B READ
- *
- ONECARD PUT OUTPUT,INCARD COPY CARD TO OUTPUT
- B READ
- *
- EOF CLOSE (INPUT,,OUTPUT) CLOSE DATA SETS
- L 13,SAVE+4 RESTORE SAVE AREA
- LM 14,12,12(13) RESTORE REGISTERS
- SR 15,15 SET RETURN CODE
- BR 14
- EJECT
- SAVE DC 18A(0) SAVE AREA
- INCARD DC CL80' ' INPUT CARD AREA
- OUTCARD DC CL161' ' OUTPUT CARD AREA
- HEXTBL DC C'0123456789ABCDEF' HEX TRANSLATE TABLE
- *
- INPUT DCB DDNAME=INPUT,DSORG=PS,MACRF=(GM),RECFM=FB,LRECL=80, *
- EODAD=EOF
- *
- OUTPUT DCB DDNAME=OUTPUT,DSORG=PS,MACRF=(PM),RECFM=FB,LRECL=80
- END
-